Follow us :

Commutator turning machine ND-WGK-2X Error E003

 Commutator turning machine PLC Mitsubishi show E003 and the drive is flickering 1 and 2.

Please follow below steps to set the P8 as 0.5,  then the problem will be sloved,
 
1. Press pu/ext, the pu indicator will light,
2. Press MODE, the P0 will appear in screen,
 
then rotate the switch  to the P8,
some data will appear in screen,
rotate  the switch to set the data as 0.5, press SET to confirm the setting,