There is an intermittent problem in Balancing machine. The machine is working normally and during the normal process, all of a sudden it shows the following value: Left side 35 and Right Side 65.
After Switching OFF and restarting, then it is working normally and the values are decreasing.
Why this inconsistency problem?
Answer:
We have checked the ground connection ,it is less than 1Volt, Also during this problem, the commissioning status shows ZERO value.
Please cut off the power and open the cabinet, there are two piece 4067 intergarated chip,
Please take a photo because they have assembly direction, then pull out the 2pcs 4067 chip,
And check if the problem will happen or not,