  • Question: In paper insertion machine some time machine is running directly.See attached video.Some problem display.Answer:Thanks for the video and problem description, Would you please also inform below information to us?1. In which speed the machine running directly, speed1, speed2 or speed 3?2. The speed vibrate some time or every time? Question: 1. In third speed2. Every timeAnswer: Please ch...

  • We study your datas and found that actually both machines have no problem with the balance armature,this means both machine are ok for balancing.Only unbalance aramture has some difference which is not much matter.We give some suggestions as below:Issue 1:New machine has higher test value.1.Change the supporting part of new machine to same as old machine's ceramic bar. (See attached photo)Note:Th...

  • Question: Wedge insertion machine.In this mechanical setting is not proper.We can not maintain this part because it can not be opened..Slider is sticking inside.Answer:There are 3 bolt on this part. 1st loosen the bolt then by using hand wheel move the slider, if the slider move clearly then again tighten the bolts

  • The are two methods to slove hook missing problem:Put on the armature, have a check if the position of armature and hook tooling is alignment,Method 1: Adjust the hook tooling a little clockwise or anti-clockwise (based on the situation) after loosening the screws;Method 2: Adjust the indexing value with 1 degree plus or minus( based on the situation) It means each time 1 degree, and the formula...

  • Question: We found the second amplifier show'AL 20'Solution:The middle amplifier is for right flier, the problem might come from machine mechanical parts blocked or phase loose or short circuit,Please follow below steps to check,1. Switch off the power, then try to rotate the right flier motor with your hand, in normal condition, it should be smooth, If you felt there is resistance, please ch...

  • Question: I check the machine start to end 1) First machine switch on 2) Do the balancing new pieces , up 12 pieces is ok 3) After 13 pieces machine become problem. Motor will no run ( switch or food switch ) to press4) After the machine will switch off .5) Then machine switch on . do the balancing motor will run .up to become problem Thanks for your detail description...

  • Question: We are getting ERROR 21 in Armature Winding machine ND-LAW-5B. Can you please send us the ERROR LIST and the diagnostic procesdureSolution:I enclosed the instruction manual, please check,Error21 is poor contact of communication,Your could check the servor motor's wire, encoder line of amplifier on the back side of the machine (cabinet)Then well connect them,

  • Question: We are facing problem in commutator turning machine.See the attached video (Run not work)Solution: Please re-connect the wire for touch screen and PLC connection:1. Manually loosen the screw for fixing the wire, and make the wire well connected,2. After that, tighten the screw,Question: Now the same problem repeated.Loosen the screw & connection two time & tighten but problem is as it i...

  • Question: 1. cycle stop function. we are tighten all electrical connection & Check but the cycle stop meter working few times then automatic not working. The power coating function ok but vibration continue. 2. Voltmeter & ammeter on Panel not working. The heating Ok but on panel voltmeter & ammeter not showing.Solution:1. Please change the two relay KT6 and KT3 ( time relay KT6 and powder coa...

  • Question: In our stator winding, all days we used 23.5 & 23 SWG aluminum wire and have no problems. Last couple of weeks we introduced 22 SWG Aluminum wire which got cut during Loop taking at middle of winding. We wind 170 + 30 Turns in stator. After 170 turns we need to take Loop wire, then wind 30 turns. This is normal Operation. In NIDE stator winder after 170 turns of wind while machine taking...

  • 1. Check if the marked place, out ring part should be 1 to 2mm on the outside of the inner ring part, If you didn't adjust it before, don't change it2. Please add the hang shifting angle a little big, add 2 to 5 and check the result,

  • Question: 1. The nozzle touch the wire 2. The indexing is not in home positionAnswer:The machine problem may caused by two reason,1. The indexing home position is not in original home position2. The needle is protected by machine protectionTo slove the problem, please follow below step:1) Turn to 'Manul control', press 'Indexing clockwise ' then turn to 'Auto control' to see if...

  • Question: COMMUTATOR TURNING MACHINE ND-WGK-2X Touch screen don't response and blink when 'Data set', Solution:Please re-connect the wire for touch screen and PLC connection:1. Manually loosen the screw for fixing the wire, and make the wire well connected,2. After that, tighten the screw,

  • Question:There is an intermittent problem in Balancing machine. The machine is working normally and during the normal process, all of a sudden it shows the following value: Left side 35 and Right Side 65. After Switching OFF and restarting, then it is working normally and the values are decreasing.Why this inconsistency problem?Answer:The intermittent problem might come from the not well ground co...

  • Question:Our Nide turning machine is showing the error message as shown in the below screen shots and not able to reset the errorSystem screen does not respond to change the below shown value ( highlighted by a circle in the picture ) and the machine is not coming to home position Kindly help to resolve this issueSolution:Based on the photo information, we found below problem,1. The rotor No is 50...

  • Question: There will two servo driver showed 'Err 11', and the screen showed 'Err11' Solution: The whole circuit is General power supply --- General air switch --- Transformer --- Fuse --- Separate air switch ,Please follow below step to check, 1. Please measure the three terminal of air swith which is at lefft side of the amplifier, Both amplifier gave out Err 11, measure their left side ...

  • Question: In commutator turning M/C cutter is not taking second cutAnswer: We checked the video and paramater, as there is little difference in 1 and 2 you set,Plese set the 2 from 3.080MM to 3.090MM or 3.100MM,

  • Commutator turning machine PLC Mitsubishi show E003 and the drive is flickering 1 and 2.Please follow below steps to set the P8 as 0.5, then the problem will be sloved, 1. Press pu/ext, the pu indicator will light,2. Press MODE, the P0 will appear in screen, then rotate the switch to the P8, some data will appear in screen, rotate the switch to set the data as 0.5, press SET to confirm the se...

  • z axis value (*******) can not be changed,single action mode z axis can move but value cannot be changedAdjust the commutator turning machine to home position, as the process when you change a cutter

  • We Turn off the machine, 5 minutes later, turn on again, then i put on 1 piece of armature, long time press the foot pedal but not run the motor.Motor not run while initially turn on the machine (at foot pedal press condition) ? From your description, we detect it is the driver problem,

  • Problem: Servo drive is not changing its figure, normally it should be a data, not a code,It is showing AL....37(continue on - off,on - off).It is flickering.NO changes when machine is running There are four press button on the servo motor driver, please follow below steps to set the parameter:1. Press the first button, P 00 will show in the screen2. Press the fouth button, then press the fouth b...

  • The winding machine's monitor doesn't respond when turning on but shows only data, there is nothing I can select as there is on menu bar shown,Please check the situation of 6 lights POWER、RUN、ERR/ALM、INT、BKUP、PRPHL,Whether they are on or off or flickering, if they are on, what is the color, red or yellow? Please take picture and describe sperately for the 6 lights. And please check the two parts ...

  • Please check the parameter setting,Flier short swing should be around 30000, and speed up running speed of flier is around 800

  • Please input oil dipping action no.in the touching screen, open the electric cabinet. Taking universal electric meter to measure the voltage of contactor---wire UL,VL,WL alternatively. Provided their value is similar and within 380-400V. It verifies the oil pump is ok. Otherwise the pump was burnt.----pls replace it. If Oil pump is ok, pls refer to fuse. From right to left, pls use universal elec...

  • Opened control panel.Remove all socket from card.Push all IC. Reassembled the socket.Set all parameter once again.Started the machine.

  • One of the flyers stops working after 15 – 20 minutes and needs to be reset to start againLeft flyer stops, the error no.21 appears. Correct?Then your engineer tighten the encoder wire of left flyer, and do the reset every time while the left flyer stops, finally the machine runs well. Correct?In this case, pls ask your engineer to exchange the encoder wire of left flyer and right flyer. If the pr...

  • AC drive.Inout is Ok but output is not getting, how to solve? There are two possibility which may cause the problem,1. The inverter have problem2. The black swith for adjusting speed have problem You could verify if inverter problem by below method, Please DO take a picture of the wires connection of inverter firstly for recording the wire connction status, then connect the yellow wire as attach...

  • In lacing machine, if the needle could mot move the thread properly, how do you slove it? 1. Adjust the needle position2. You could check if the speed and action of the needle and nozzle are not synchronous, you could adjust the endoder,Actually for changing tooling of the lacing machine, if OD difference is big, adjust the stroke by move the base forward or backwardIf the stack height is changed...

  • For armature winding machine ND-LAW-2 ( for small wire diameter )The are two methods to slove hook missing problem: Put on the armature, have a check if the position of armature and hook tooling is alignment, Method 1: Adjust the hook tooling a little clockwise or anti-clockwise (based on the situation) after loosening the screws, Method 2: Adjust the indexing value with 1 degree plus or minus(...